| MECHANICAL PRESSURE REGULATED VARIABLE FLOW PALETTE PUMPS | ||||
| Type | Displacement | Min-Max Speed | Max. Pressure | |
| PVF | cc/rev | rpm | bar | |
| PVF-12-070 | 6.6 | 800 - 1800 | 50 - 70 | |
| PVF-20-070 | 11.1 | 800 - 1800 | 50 - 70 | |
| PVF-30-070 | 16.6 | 800 - 1800 | 50 - 70 | |
| PVF-40-070 | 22.2 | 800 - 1800 | 50 - 70 | |
| PRE-WARNING PRESSURE REGULATED VARIABLE FLOW PALETTE PUMPS | ||||
| Type | Pump | Displacement | Min-Max Speed | Max. Pressure |
| VP.F | Type | cc/rev | rpm | bar |
| VP5F-A-3 | ― | 16.6 | 800-1800 | 70 - 140 |
| VP5F-B-3 | ― | 22.2 | 800-1800 | 20 - 70 |
| VP5FD-A-5-A-5 | Tandem | 16.6+16.6 | 800-1800 | 70-140 |
| VP5FD-B-3-B-3 | Tandem | 22.2+22.2 | 800-1800 | 20 - 70 |
| MECHANICAL PRESSURE REGULATED VARIABLE FLOW TANDEM PALETTE PUMPS | ||||
| Type | Pump | Displacement | Min-Max Speed | Max. Pressure |
| PVDF | Type | cc/rev | rpm | bar |
| PVDF-20+20-070 | Tandem | 11.1 +11.1 | 800 - 1800 | 50 -70 |
| PVDF-30+30-070 | Tandem | 16.6+16.6 | 800 - 1800 | 50 -70 |
| PVDF-40+40-070 | Tandem | 22.2+22.2 | 800 - 1800 | 50-70 |